Flame Sensor FS-3500E

The FS-3500 Flame Sensor immediately detects UV rays contained in flames to trigger a pre-recorded “flame prohibition” or “non-smoking” message output in a choice of 5 languages; English, Spanish, Japanese, Chinese and Korean.

Ref. FS-3500E Category: Tag:

Description

The FS-3500 Flame Sensor immediately detects UV rays contained in flames to trigger a pre-recorded “flame prohibition” or “non-smoking” message output in a choice of 5 languages; English, Spanish, Japanese, Chinese and Korean. The sensor can be powered from two type-AA alkaline batteries (supplied) or hardwired (10-30VDC), and features a detachable base unit with a snap-in/out design for easy installation.

Features:

  • Up to 10m (33ft) UV detection
  • Pre-recorded flame prohibition and non-smoking messages in 5 languages
  • Long/short message selectable
  • Detachable base unit with snap-in/out sensor design for easy installation
  • Battery (2x type-AA alkaline supplied) or 10-30VDC operation

Specifications

  • Model: FS-3500E
  • Detection system: Ultraviolet rays detection (185~260nm)
  • Detection distance: 10m (33ft) max. (7cm flame)
  • Detection angle: 120 degrees (conically)
  • Detection Sensitivity adjustment: Detection Sensitivity: 2 levels – H (100%), L (50%) – Detection Timer: 4 steps (1s, 3s, 6s, 15s)
  • Power supply Type-AA alkaline battery (LR6) 2pcs / DC3V – included – External wiring 10-30VDC (Polarized)
  • Battery life: Type-AA alkaline battery: Approx. 2 years (stand-by) – (Note: above figure is for reference only and not guaranteed)
  • Power consumption (External DC power): Standby: 40mA or less – Alarm: 300mA or less
  • Signal output: Relay contact output NO/NC selectable – Detection time plus 2 sec. – Output DC30V 0.1A
  • LED Indication: RED – Alarm: Flash during message output low battery: flash 0.1sec every 5sec
  • Wiring: Reed wiring – Power supply: 2 / dry contact: 3
  • Message: • 5 languages – Non-Smoking;
    ENGLISH: “This is a non-smoking area. Please refrain from smoking in this area.”
    SPANISH: “Prohibido fumar. Abstengase de fumar en el servicio.”
    Flame prohibition;
    ENGLISH: “Open flame is prohibited. Please refrain from using open flame in this area.”
    SPANISH: “Prohibido encender fuego. No se permite el uso de productos inflamables en el servicio.”
    Buzzer sound: PiPiPiPi
    • Long/short message selectable
    • Message repeat: once/twice selectable
    • Volume: Mute – Max 80dB (1m from the sensor)
  • Tamper: Relay contact output NC is issued when the sensor is detached from the base unit – Output AC/DC30V 0.1A
  • Wiring: By terminals
  • Ambient temperature: -10°C to +60°C (+14°F to +140°F) without condensation
    (battery performance may decrease below 0°C and above 40°C)
  • Installation: Indoor
  • Functions: Tamper signal, Low battery indication
  • Appearance: ABS resin (white)

Accesories